NEW UC INSTRUMENTS GM81022CL SALES and UC INSTRUMENTS GM81022CL CALIBRATION

 
Custom-Cal has for sale a new UC INSTRUMENTS GM81022CL. Also, short calibration turn times minimize downtime and reasonable rates decrease your long-term cost of ownership and minimizes downtime of the UC INSTRUMENTS GM81022CL. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Tunable Laser Source (TLS)?
Shop for Comparable Products on our
 used Tunable Laser Source (TLS) page or new Tunable Laser Source (TLS) page

 
List Price for a new UC INSTRUMENTS GM81022CL, $13,650.00   UC INSTRUMENTS GM81022CL   Description / Specification:   Spec Sheet 
UC INSTRUMENTS GM81022CL C+L-Band Tunable Laser Module

The UC INSTRUMENTS GM81022CL Tunable Laser Module offers superior performance for the test of DWDM components, AWG & PLC components, optical amplifiers, and other general purpose of fiber optical test and measurement applications. A GM8001B mainframe can host 2 Tunable Laser modules. Specifications. Wavelength range: 1525.00 to 1610.00 nm. Output Power: >= 7 dBm. Wavelength resolution: 1.0 pm. Absolute wavelength accuracy: +/- 10 pm, tpy. < 5 pm. Relative wavelength accuracy: +/- 5 pm, Typ. +/- 2 pm. Wavelength repeatability: +/- 2 pm, typ. +/- 1 pm. Wavelength stability (typ., 24 hrs at constant temperature: <= +/- 2 pm. Tuning speed: <= 2 ms per step. Power stability: +/- 0.05 dB, 1 hour. Typ., +/- 0.1 dB, 24 hours. Power repeatability: +/- 0.05 dB. Power linearity: +/- 0.3 dB. Power flatness versus wavelength: 0.3 dB typ., 0.5 dB max.. Side-mode Suppression ratio: >= 50 dBc. Relative intensity noise (RIN. Typ.): < -135 dB. Output optical interface: PM, FC/PC connector. Dimensions: 75 mm H, 32 mm W, 310 mm D [3.5" (L) x 8.5" (W) x 12.5" (H)].



 

Standard Calibration $540.00 *
*This is a Web introductory price for one calibration of the UC INSTRUMENTS GM81022CL. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bit Error Ratio (BER)
Bit Error Ratio (BER) is the ratio of errors caused by the number of bits in a data stream that have been altered due to noise, interference, distoriton or bit synchronization errors.

Flatness
Variation of insertion loss on the passband of an optical device.

Polarization Dependent Loss (PDL)
Polarization Dependent Loss is the difference between the maximum and minimum values of loss due to the variation of the polarization states of light propagating through a device. PDL is expressed in decibels. Calculated by; PDL = 10 log10 (Ep/Es), where EP and ES are the measured diffraction efficiencies for P- and S-plane polarized incident light, respectively.

Return Loss (RL)
Return Loss (RL) is the ratio of the incident power to the reflected power expressed in dB. RL = 10log (Pin/Pback)

Wavelength Resolution
Wavelength Resolution is the smallest possible displayed wavelength increment/decrement.


Please contact us for your new UC INSTRUMENTS GM81022CL sale price and/or UC INSTRUMENTS GM81022CL CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: